NovaSTREAM 6000 TCD
The NovaSTREAM 6000-TCD Analyser for use in hazardous areas of Zone 1 and Zone 2 classification.
Wall Mounted Gas Analyser - Ex
% and ppm analysis using Thermal Conductivity Detector
The NovaSTREAM 6000-TCD Analyser is explosion proof utilising a Purge method of conformity, and is housed in a mild steel enclosure for use in the hazardous areas of Zone 1 and Zone 2 classification. This specially designed enclosure enables real-time analysis in hazardous areas with reliable and consistent results.
The core of this analyser system is the NovaSTREAM 6000 Analyser platform using the unrivalled Thermal Conductivity Detector (TCD) of which AGC Instruments is a leading supplier worldwide. This versatile and robust detector design is ideal for permanent gas analysis and its universal applicability ensures that it is both cost effective and reliable. Using hotwire or thermistor elements, it achieves high accuracy and sensitivity with a response time of < 30 seconds (T90). The temperature regulated TCD allows continuous monitoring of the gas stream and stability is guaranteed with < 1% drift over a 24 hour period. Through the additional use of solenoid valves, drift can be eliminated as a constant reference to Zero gas is utilised for greater accuracy. For example, one of the primary applications using the TCD Cell Model Number 10-454-2 is for measuring
N2 in H2 with results less than 5 ppm achieved.
Features:
- Explosion Proof for use in Zone 1 and Zone 2
- Cabinet fitted with Purge Controller to EExP standards
- Also available in safe zone configuration
- Thermal Conductivity Detector (TCD)
- Detector variations designed and built to spec
- Ideal for Binary Gas Mixtures or Pure Gases
- Fast Detector Response: < 30 seconds (T90)
- Long Term Stability & Sensitivity
- 6.5” LCD Touch Screen with 6mm Protective Glass
- Fully Automated use with intuitive GUI
- Integrated Configurable Alarms System with Alarm Record
- Added Sample Flow Alarm
- Integrated Diagnostics System
- Flow Sensors
- Voltage free contacts for switching in calibration gas inputs externally
- Auto-Calibration Routine with Calibration Record
- Internal storage of results up to 24 months and data trending via PC
- External I/O Connections for internally pre-wired communication modules: 2 x 4-20mA, 1 x mV Signal, VGA & USB Outputs
- Ethernet, Modbus over TCP/IP & Profibus options
- Easy Access for maintenance and servicing
- Cost Effective and Reliable
Typical Industries
- Hydrogen Plants
- Air Liquefaction plants
- Chemical Plants
- Refrigeration Plants
- Iron and Steel Industry
- Air Separation Units
- Gas Blending Equipment
- Refineries
- Ammonia Plants
- Industrial Gas Production Units
- Power Generation Plants